ANDO AQ-6315B REPAIR and ANDO AQ-6315B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ANDO AQ-6315B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANDO AQ-6315B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   ANDO AQ-6315B (AQ6315B)   Description / Specification:   Spec Sheet 
ANDO AQ-6315B 350 to 1750 nm Optical Spectrum Analyzer

The Ando AQ-6315B optical spectrum analyzer brings advanced capabilities to a wide range of applications, from light source evaluation to measurement of loss wavelength characteristics in optical devices. Features. The monochromator mode can be set to single-pass or double-pass to match your measurement application needs. Provides a dynamic range (stray light level) of 70dB or more ± 1 nm from the peak. This is especially valuable when measuring DFB-LD side-mode suppression ratio. Covers from 350nm to 1750nm and noise level has been suppressed to allows the AQ-6315B to measure light at down to -90dBm. Polarization dependency has been slashed to ± 0.05dB, enabling accurate measurement of optical amplifier gain and other critical measurements. Optical output is provided, can be used as an optical bandpass filter. 9.4-inch color LCD. Specifications. Measurement wavelength range: 350 to 1750 nm. Wavelength span: 0 to 1500 nm. Wavelength accuracy: ±0.5nm (25 ±5°C, 10/125 SM fiber). Wavelength reproducibility: ± 0.005nm (1 minute). Wavelength resolution: 0.05 to 10 nm. Level accuracy: ± 0.3dB (at 633/1310/1550nm). Interface GP-IB.



 

Standard Calibration $785.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANDO AQ-6315B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your ANDO AQ-6315B REPAIR and/or ANDO AQ-6315B 350 to 1750 nm Optical Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: