FLUKE 175 CALIBRATION and FLUKE 175 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 175 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 175   Description / Specification:    
FLUKE 175 Handheld True RMS Digital Multimeter

The Fluke 175 True RMS digital multimeter gives you voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. Specifications. Voltage DC: Accuracy ± (0.15%+2), Max. Resolution 0.1 mV, Maximum 1000 V. Voltage AC: Accuracy ± (1.0%+3), Max. Resolution 0.1 mV, Maximum 1000 V. Current DC: Accuracy ± (1.0%+3), Max. Resolution 0.01 mA, Maximum 10 A. Current AC: Accuracy ± (1.5%+3), Max. Resolution 0.01 mA, Maximum 10 A. Resistance: Accuracy ± (0.9%+1), Max. Resolution 0.1 ohm, Maximum 50 M-ohm. Capacitance: Accuracy ± (1.2%+2), Max. Resolution 1 nF, Maximum 10,000 µF. Frequency: Accuracy ± (0.1%+1), Max. Resolution 0.01 Hz, Maximum 100 kHz.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 175. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your FLUKE 175 CALIBRATION and/or FLUKE 175 Handheld True RMS Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: