The HP 70950A is a 1700 nm Optical Spectrum Analyzer Module for 70000 Modular Measurement System (MMS). It is a 1/2 width module with FC/PC connectors standard. Sensitivity is -80 dBm and dynamic range is 60 dB 1 nm away from the signal. The resolution is 0.1 to 10 nm in a 1,2,5 sequence. The input connector system has a wide choice of adapter options. It offers three advanced functions to measure and characterize LED, DFB, or Fabry-Perot lasers. Specifications. Wavelength Range: 600 to 1700 nm. Wavelength Tuning repeatability: ±0.005 nm. Wavelength Span Range: 0.2 nm to full range. Wavelength Absolute Accuracy: ±1 nm. Maximum Sensitivity (1100-1600 nm): –90 dBm.Sweep Time sensitivity in auto, full span: < 0.5 seconds. Input Power, 1 dB compression level within resolution: =10 dBm. Dynamic Range: -50 dB at = ± 1 nm(600 to 1700 nm), -55 dB at = ± 0.5 nm(1250 to 1600 nm). Resolution: 0.08 nm, 0.1 nm, 10 nm (in a 1,2,5 sequence). Options. 001, Programmable Current Source. 002, Built-in White Light Source. 010, Delete FC/PC Interface. 051, EDFA Test Personality. 101, Enhanced Polarization Sensitivity.
|
|
The Deviser E8600 is a high-precision diffraction-grating, high-resolution optical spectrometer with wavelength range of 600 nm to 1700 nm. The 10.1” LCD touchscreen and concise graphical user interface of AE8600 offer the easiest way to handle optical spectrum analysis. It provides a wide selection of test methodology, including laser spectrum scans (DPB, FP), WDM system testing, EDFA system testing, transmittance and drift testing, which are essential for in-field and factory applications. The AE8600 offers exceptional stability and reliability, high-speed spectral sweeping, and multiple ways to export and analyze measurement data. It’s the ideal instrument for fast and precise optical spectral testing to satisfy long-term investment with the best cost performance value. Specifications.
Optical Spectrum Measurement. Wavelength range: 600 to 1700nm. Wavelength resolution bandwidth: 0.02 to 2nm. Wavelength resolution setting: 0.02nm, 0.06nm, 0.1nm, 0.2nm, 0.5nm, 1nm, 2nm. Wavelength accuracy; 1520 to 1620 nm ±0.02 nm, 1450 to 1520 nm ±0.04 nm, Entire wavelength range ±0.1 nm. Wavelength repeatability: ±0.005 nm (1 minute). Wavelength linearity; ±0.01 nm (1520 to 1580 nm), ±0.02 nm (1450 to 1520 nm, 1580 to 1620 nm). Minimum sampling resolution: 0.001nm. Applicable fiber: SM(9.5/125μm), MMF(50/125μm, 62.5/125μm).
Optical Power Measurement. Level sensitivity; -90dBm (1300-1620nm, resolution ≥0.05nm), -85dbm (1000-1300nm, resolution ≥0.05nm), -60dBm (600 - 1000nm, resolution ≥0.05nm). Maximum input power: +20dBm. Level accuracy: ±0.4dB (1310/1550nm, input level -20dBm). Level linearity: ±0.05dB( input level: -50 to +10dBm). Wavelength sampling points (Maximum): 50,000. Optical return loss: >35dB (with angled-PC connector). Polarization dependence: ±0.05dB (1550nm). Dynamic range; Peak ±0.1nm 39dB (Resolution: 0.02nm), Peak ±0.4nm 60dB (Resolution: 0.05nm).
|