TEKTRONIX DC5009 CALIBRATION and TEKTRONIX DC5009 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DC5009 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   TEKTRONIX DC5009   Description / Specification:    
TEKTRONIX DC5009 Programmable Universal Counter / Timer Plug-in

The Tektronix DC 5009 single-width Programmable Universal Counter / Timer provides all of the measurement functions of the higher performance DC 5010/ DC 510 except rise time/fall time, null, and totalize A ± B. The powerful reciprocal-frequency measurement technique allows up to eight digits of resolution of low-frequency signals in one second or less of measurement time. The DC 5009 has the same automatic averaging feature as the DC 5010/ DC 510; selected averaging of up to 108 events provides usable time-interval resolution of 5 ps. Channel A and Channel B Input; Frequency Range - >0 to >= 135 MHz DC coupled. <= 10 Hz to >= 135 MHz AC coupled. Sensitivity - <= 20 mV RMS (56.6 mV p-p) to >= 100 MHz, 40 mV RMS (113 mVp-p) from 100 MHz to >= 135 MHz, 115 mV p-p at minimum, pulse width of 3 ns. Attenuation Selectable - 1X, 5X. Impedance - 1 M-ohm ±2% paralleled by <= 30 pF. Trigger Level Range - +3.200 to -3.175 V with 25 mV resolution (X1), + 16 to -15.875 V with 125 mV resolution (x5). Trigger Level Accuracy - ±15 mV ±40 uV/°C referenced to 25°C. Dynamic Range - 3.2 <= input voltage <= +3.2 . X1: Vin p-p <= 3 V; X5: Vp-p 15 Vin (for input signal risetime p-p <= 3 V; X5: Vp-p 15 Vin); (for input signal risetimes <= 5 ns). Autotrigger Frequency Range - Sensitivity <= 125 mV p-p x attenuation; <= 20 Hz to >= 100 MHz. Range: ±3.2 V x attenuation. Resolution: 25 mV x attenuation. Independent Controls - Slope ±, attenuation 1X / 5X, Couple AC/DC, Source Internal/External. Frequency A Range: <= 100 uHz to >= 135 MHz. Accuracy Resolution: ±(Time Base Error x Frequency A). Rise / fall A Range - 7.4 ns to 3.05 hrs.



 

Standard Calibration $345.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DC5009. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX DC5009 CALIBRATION and/or TEKTRONIX DC5009 Programmable Universal Counter / Timer Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: