3M 701 CALIBRATION and 3M 701 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the 3M 701 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   3M 701   Description / Specification:    
3M 701 Test Kit for Static Control Surface

The 3M 701 Test Kit Contains A Lightweight, User-Friendly Megohmmeter Plus All Of The Components Needed To Make Testing Mats And Other Surfaces Simple And Accurate. All Of The Items Are Packaged In A Foam-Lined Carrying Case. Specifications. Continuity Measurement Range: 0 to 10 Mohm. Continuity Open Circuit Voltage: 10 V ± 0.7 V. Continuity Internal Resistance: 500 ohm. 10 V Surface Measurement Range: 10^5 to 10^11 ohm. 10 V Surface Open Circuit Voltage: 10 V ± 0.7 V. 10 V Surface Internal Resistance: 2 ohm. 100 V Surface Measurement Range: 10^5 to 10^11 ohm. 100 V Surface Open Circuit Voltage: 100 V ± 0.7 V. 100 V Surface Internal Resistance: 2 ohm. Battery Test: Internal test of 100V source – Accuracy: ± 2% ± 2° of arc.



 

Standard Calibration $185.00 *
*This is a Web introductory price for one calibration of the 3M 701. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your 3M 701 CALIBRATION and/or 3M 701 Test Kit for Static Control Surface REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: