GIGATRONICS 80303A CALIBRATION and GIGATRONICS 80303A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the GIGATRONICS 80303A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   GIGATRONICS 80303A   Description / Specification:   Spec Sheet 
GIGATRONICS 80303A 26.5 GHz, Type K(m), CW Power Sensor

The Giga-tronics 80303A CW Power Sensor lets you measure CW power from 10 MHz to 26.5 GHz at more than 1,750 readings per second over GPIB. Measure up to 90 dB with a single sensor. Measurement Capabilities.
Specifications.
Frequency Range: 10 MHz to 26.5 GHz.
Power Range CW: -70 to +20 dBm.
Maximum Power:
+23 dBM, 200 mW.
Power Linearity (Frequency > 8 GHz):
  -70 to -20 dBm: ±0.00 dB,
  -20 to +20 dBm: ±0.1 dB/10 dB.
VSWR:
  1.12: 0.01 - 2 GHz,
  1.22: 2 - 12.4 GHz,
  1.38: 12.4 - 18 GHz,
  1.43: 18 - 26.5 GHz.
RF Connector: Type K(m) 50 Ω.



 

Standard Calibration $270.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the GIGATRONICS 80303A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your GIGATRONICS 80303A CALIBRATION and/or GIGATRONICS 80303A 26.5 GHz, Type K(m), CW Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: