GIGATRONICS 80304A CALIBRATION and GIGATRONICS 80304A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the GIGATRONICS 80304A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   GIGATRONICS 80304A   Description / Specification:   Spec Sheet 
GIGATRONICS 80304A 40 GHz, Type K(m), CW Power Sensor

The Giga-tronics 80304A CW Power Sensor lets you measure CW power from 10 MHz to 40 GHz at more than 1,750 readings per second over GPIB. Measure up to 90 dB with a single sensor. Measurement Capabilities.
Specifications.
Frequency Range: 10 MHz to 40 GHz.
Power Range CW: -70 to 0 dBm.
Maximum Power:
+23 dBM, 200 mW.
Power Linearity (Frequency > 8 GHz):
  -70 to -20 dBm: ±0.00 dB,
  -20 to 0 dBm: ±0.2 dB/10 dB.
VSWR:
  1.12: 0.01 - 2 GHz,
  1.22: 2 - 12.4 GHz,
  1.38: 12.4 - 18 GHz,
  1.43: 18 - 26.5 GHz,
  1.92: 26.5 - 40 GHz.
RF Connector: Type K(m) 50 Ω.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the GIGATRONICS 80304A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your GIGATRONICS 80304A CALIBRATION and/or GIGATRONICS 80304A 40 GHz, Type K(m), CW Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: