GIGATRONICS 80601A CALIBRATION and GIGATRONICS 80601A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the GIGATRONICS 80601A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   GIGATRONICS 80601A   Description / Specification:   Spec Sheet 
GIGATRONICS 80601A 18 GHz Modulated Power Sensor

The Giga-tronics 80601A 18 GHz Modulated Power Sensor provides bandwidth up to 1.5 MHz to measure the peak and average power of CDMA signals. Measurement Capabilities. CW Power Level: –67 to +20 dBm. Amplitude Modulation Rate, Power Range: fm <= 1.5 MHz (–60 to +20 dBm), fm > 1.5 MHz (–60 to -20 dBm). Two-Tone Maximum Separation Between Carriers: –60 to +20 dBm (<= 1.5 MHz), –60 to -20 dBm (> 1.5 MHz). Pulse Modulation: > 300 µs Pulse Width. Frequency Range/Power Range: 10 MHz to 18 GHz (–67 to +20 dBm, CW). Maximum Power: +23 dBm (200 mW). Power Linearity Frequency >8 GHz: ±0.00 dB (–67 to –20 dBm), ±0.05 dB/10 dB (–20 to +20 dBm). RF Connector: Type N(m), 50 ohm. VSWR: 1.12 (0.01 - 2 GHz), 1.22 (2 - 12.4 GHz), 1.29 (12.4 - 18 GHz).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the GIGATRONICS 80601A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your GIGATRONICS 80601A CALIBRATION and/or GIGATRONICS 80601A 18 GHz Modulated Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: