INSTEK GDS-2202 CALIBRATION and INSTEK GDS-2202 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GDS-2202 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   INSTEK GDS-2202   Description / Specification:    
INSTEK GDS-2202 2 Ch 200 MHz Digital Storage Oscilloscope

The GW Instek GDS-2202 is a generic purpose digital storage oscilloscope suitable for wide range of applications such as production testing, research, and field verification. It features a powerful display, 5.6 in. color TFT, wide viewing angle, 8 x 12 divisions waveform support and USB connection to printers and storage devices. Specifications. Channels: 2. Bandwidth: DC to 200 MHz (-3dB). Rise Time: 1.75 ns approx. Sensitivity: 2 mV/div to 5 V/Div (1-2-5 increments). Accuracy: ± (3% x |Readout|+0.05 div x Volts/div). Input Coupling: AC, DC, & Ground. Input Impedance: 1 M-ohm ±2%, ~16 pF. Bandwidth Limit: 20MHz (-3 dB). Horizontal Range: ±15 V. Accuracy: ±0.01%. Trigger Sources: CH1, CH2, Line, EXT. Trigger Sensitivity: DC to 25 MHz Approx. 0.5 div or 5 mV. Signal Acquisition Real-Time: 1G Sa/s maximum. Signal Acquisition Equivalent: 25G Sa/s maximum. Record Length: 25K Dots Maximum. Acquisition Mode: Sample, Peak Detect, Average, Accumulate. Ext Trigger Range: ±15 V. Ext Trigger Sensitivity: DC to 30 MHz, ~50 mV; 30 MHz to max, ~100 mV.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GDS-2202. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your INSTEK GDS-2202 CALIBRATION and/or INSTEK GDS-2202 2 Ch 200 MHz Digital Storage Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: