INSTEK GFG-8219A CALIBRATION and INSTEK GFG-8219A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GFG-8219A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   INSTEK GFG-8219A   Description / Specification:   Spec Sheet 
INSTEK GFG-8219A 3 MHz Function Generator w/Counter, Sweep Mode, AM/FM

The Instek GFG-8219A 3 Mhz Function Generator With Counter output waveforms are Sine, Triangle, Square, Ramp, TTL and CMOS. It has External Voltage Controlled Frequency (VCF) Function, Duty Cycle Control with Signal Inversion Capability, Variable DC Offset Control and a Two-Step (-20dBx2) and Variable attenuator. The Instek GFG-8219A has a built-in 6 Digit Counter with INT/EXT Function up to 150 MHz and INT/EXT AM/FM Modulation. Specifications. Frequency Range: 0.3 Hz to 3 MHz (7 Range). Amplitude: > 10 Vpp (into 50 ohm load). Impedance: 50 ohm ±10%. Attenuator: -20 dB ±1 dB x 2. DC Offset: <-5V to >5V (into 50 ohm load). Duty Control: 80% : 20% : 80% to 1MHz Continue variable. Sine Wave Distortion: <=1%, 0.3 Hz to 200 kHz THD <=35 dB below fundamental in all range (Specification applied from MAX. to 1/10 level). Sine Wave Flatness: < 0.3 dB, 0.3 Hz to 300kHz, < 0.5 dB, 300 kHz to 3 MHz. Triangle Wave Linear: >= 98% 0.3 Hz to 100 kHz, 95% 100 kHz to 3 MHz. Square Wave Symmetry: ±2%, 0.3 Hz to 100 kHz. Square Wave Rise or Fall Time: <= 100 nS at maximum output (into 50 ohm load). Sweep/Rate: 100 : 1 ratio max. and adjustable. Sweep/Time: 0.5 sec. to 30 sec. adjustable. AM Depth: 0 to 100%. AM MOD. Frequency: 400 Hz (INT), DC to 1 MHz(EXT.). FM Deviation: 0 to ±5%. FM MOD. Frequency: 400 Hz (INT), DC to 20 kHz(EXT.). Frequency Counter Range: 0.3 Hz to 3 MHz (5 Hz to 150 MHz EXT.) Frequency Counter Accuracy: Time base accuracy 1 count.



 

Standard Calibration $105.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GFG-8219A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your INSTEK GFG-8219A CALIBRATION and/or INSTEK GFG-8219A 3 MHz Function Generator w/Counter, Sweep Mode, AM/FM REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: