INSTEK GPC-1850D CALIBRATION and INSTEK GPC-1850D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GPC-1850D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   INSTEK GPC-1850D   Description / Specification:    
INSTEK GPC-1850D Triple Output DC Power Supply

The GW Instek GPC-1850D is a triple output, 195W, linear DC power supply. Channel 1 and 2 are fully adjustable and Channel 3 is fixed at 5 V / 3 A with ripple and noise at less than 2 mVrms. Overload and reverse polarity protection keep it and its loads safe from unexpected conditions. The GPC-1850D features continuous or dynamic internal load selection and serial or parallel tracking for application flexibility. Specifications. DC Output CH1 / CH2: 0 to 18 V / 0 to 5 A. DC Output CH3: 5 V / 3 A Max. Operation Modes: Independent, Ch1/Ch2 Series, Ch1/Ch2 Parallel. Constant Voltage (CV) Operation Line Regulation: <= 0.01% + 3 mV. CV Operation Load Regulation: <= 0.01% + 3 mV (rating current <= 3 A) <= 0.01% + 5 mV (rating current <= 10 A). CV Ripple & Noise: <= 1 mVrms 5 Hz to 1 MHz. Constant Current (CC) Operation Line Regulation: <= 0.2% + 3 mA. CC Operation Load Regulation: <= 0.2% + 3 mA. Ripple Current: <=3 mArms. 5 V Fixed Output Line regulation: <= 5 mV. 5 V Fixed Output Load regulation: <= 10 mV. 5 V Fixed Output Ripple & Noise: <= 2 mVrms. Meter 3 1/2 digits 0.5" LED display. Meter Accuracy: ±( 0.5% of rdg + 2 digits ).



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GPC-1850D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your INSTEK GPC-1850D CALIBRATION and/or INSTEK GPC-1850D Triple Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: