KEITHLEY 580 CALIBRATION and KEITHLEY 580 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 580 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   KEITHLEY 580   Description / Specification:    
KEITHLEY 580 Micro-ohmmeter

Micro-ohmmeter: This Micro Ohmmeter features seven ranges from 200 milliohms to 200 kilohms. Maximum resolution is 10 micro ohms. The 580 features digital calibration through the front panel or via the optional gpib bus. Calibration constants are stored in non volatile RAM. It has dry circuit test modes that limit the applied voltage to 20mV on the three lowest ranges. Relative reading displays permit subtraction of base readings. A choice of pulsed current or positive or negative DC current is selectable.



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 580. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your KEITHLEY 580 CALIBRATION and/or KEITHLEY 580 Micro-ohmmeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: