KEITHLEY 595 CALIBRATION and KEITHLEY 595 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 595 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   KEITHLEY 595   Description / Specification:    
KEITHLEY 595 Quasistatic C-V Meter

Quasistatic CV Meter: This Quasistatic Calibration and Verification source has been designed to calibrate capacitance measurement equipment operating at frequencies to 1MHz. The sources are specified at 1KHz, 100KHz, and 1MHz, and the conductance sources are specified at DC, 100KHz, and 1MHz. 3 terminals (shielded). Rapid assurance of device equilibrium. Superior signal to noise performance, even with the slow voltage sweeps required by today's state of the art devices. DC current 1fA to 200µA. Capacitance 10fF to 20nF. Conductance source DC, 100KHz, and 1MHz.



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 595. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your KEITHLEY 595 CALIBRATION and/or KEITHLEY 595 Quasistatic C-V Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: