KEITHLEY 6221 CALIBRATION and KEITHLEY 6221 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 6221 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   KEITHLEY 6221   Description / Specification:   Spec Sheet 
KEITHLEY 6221 AC and DC Current Source

AC and DC Current Source. DC currents from 100fA to 105mA, AC currents from 4pA to 210mA peak to peak. The output voltage compliance (which limits the amount of voltage applied when sourcing a current) can be set from 0.1V to 105V in 10mV steps. Built-in standard and arbitrary waveform generators with 1mHz to 100kHz frequency range. Programmable pulse widths as short as 5µs. Output Resistance: >10^14 ohms (2nA/20nA range). Output Capacitance: <10pF, <100pF Filter ON (2nA/20nA range).



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 6221. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your KEITHLEY 6221 CALIBRATION and/or KEITHLEY 6221 AC and DC Current Source REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: