KEITHLEY 7402 CALIBRATION and KEITHLEY 7402 REPAIR

The KEITHLEY 7402 is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 7402 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Data Acquisition?
Shop for Comparable Products on our
 used Data Acquisition page

 
   KEITHLEY 7402   Description / Specification:    
KEITHLEY 7402 Thermocouple Scanner Card

The Keithley 7402 Nine Channel Thermocouple Scanner Card permits monitoring of up to nine thermocouples or other transducers. The nine signal channels use a guarded 2-pole configuration. An isothermal block provides electrical isolation up to 42 V while assuring excellent thermal conductivity between cold junction terminations. A sensing device mounted in the isothermal block monitors the cold junction and outputs a calibrated reference voltage that is linearly related to the temperature. Specifications. Number of Channels: 9. Card Configuration: Multiplexer. Contact Configuration: 2 form A. Maximum Voltage: 110 V. Maximum Current: 1 A. Maximum Power: 60 VA. Contact Potential: <1 uV. Contact Life: >10^8 closures cold switching; >10^6 closures at maximum signal levels. Connection Type: Screw terminal. Temperature Offset: ±0.05° C maximum from HI to LO of any channel or between any two adjacent channels in one column on the isothermal block. ±0.1° C maximum between any two terminals on the isothermal block. Maximum additional dynamic offset due to 10°C step change in environment: ±0.1°C after one hour settling. Reference Output: +200 uV/C (+54.63 mV at 0°C).



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 7402. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your KEITHLEY 7402 CALIBRATION and/or KEITHLEY 7402 Thermocouple Scanner Card REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: