ADVANTEST R3271A REPAIR and ADVANTEST R3271A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ADVANTEST R3271A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ADVANTEST R3271A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   ADVANTEST R3271A   Description / Specification:    
ADVANTEST R3271A 26.5 GHz Spectrum Analyzer

The Advantest R3271A 26.5 GHz spectrum analyzer is designed to analyze pulse RF signals used for radar or to analyze the spectrums of microwaves and quasi-millimetric waves used for satellite broadcasting, satellite communications or mobile communication. This spectrum analyzer can measure the ultra-broad bandwidth of 100 Hz to 26.5 GHz in one sweep operation. It can also perform continuous sweeps, and repeatedly. A high-purity synthesizer enables a high signal purity of-110 dBc/Hz (10 kHz offset frequency) in a frequency band of 2.5 GHz. The R3271A is thus ideally suited for mobile radio communications, for which narrower bandwidths and digitalization are being advanced. The series features a BASIC controller which allows measured data or set conditions to be stored and free construction of automatic measurement systems without the need for external controllers. Specifications. Frequency range: 100 Hz to 26.5 GHz. Preselector: 3.5 to 26.5 GHz using internal YIG tuned preselector. Frequency readout accuracy (Start, Stop, CF, Marker): ± (freq. readout x freq. reference accuracy + span x span accuracy + 0.15 x RBW + 10 Hz). Span accuracy: ± 3% (span > 2MHz), ± 5% (span <= 2 MHz). Frequency stability Residual FM (zero span): <3 Hz x Np-p/0.1 s. Frequency Linear span Range: 200 Hz to 26.5 GHz, zero span. Frequency Linear span Accuracy: ± 3% (span > 2 MHz), ± 5% (span <= 2 MHz). Resolution bandwidth (3dB) Range: 10 Hz to 3 MHz 1, 3, 10 sequence. Amplitude range: +30 dBm to average display noise level. Maximum input: Average continuous power +30 dBm (1 W) (Input atten >= 10 dB). Input attenuator range: 0 to 70 dB (10 dB step). Sweep time Zero Span: 50 us to 1000 s and manual sweep.



 

Standard Calibration $595.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ADVANTEST R3271A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your ADVANTEST R3271A REPAIR and/or ADVANTEST R3271A 26.5 GHz Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: