ADVANTEST TR5823 CALIBRATION and ADVANTEST TR5823 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ADVANTEST TR5823 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   ADVANTEST TR5823   Description / Specification:    
ADVANTEST TR5823 Universal Counter

The Advantest TR5823 is a universal counter capable of measuring frequencies from 1 mHz to 1300 MHz. The TR5823 can measure periods from 20 ns to 1000 s and can make time interval measurements from 200 ns to 1000 s. Frequency ratio and totalization measurements can also be done from DC to 50MHz. For frequencies between 1 mHz and 50 MHz (INPUT B), the TR5823 uses the reciprocal method to find the frequency by measuring the period of the input frequency and then taking the reciprocal with the internal microprocessor to calculate the frequency. From 10 Hz to 120 MHz (INPUT A), the TR5823 uses the direct measurement method. The TR5823 uses the prescale method between 100 MHz and 1300 MHz (INPUT C). Due to these various methods of measurement, accurate measurement of frequencies from low to high can be obtained from a single unit. The TR5823 also features a Masking Function, Autotrigger Function and can perform a self-check. When used with the TR1644, the TR5823 can do calculations on the measured results. The TR5823 comes with either built-in GPIB or BCD output. These features allow for system upgrading or automatic recording of measured results.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ADVANTEST TR5823. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your ADVANTEST TR5823 CALIBRATION and/or ADVANTEST TR5823 Universal Counter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: