AEMC 3710 CALIBRATION and AEMC 3710 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC 3710 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC 3710 (1221.01)   Description / Specification:   Spec Sheet 
AEMC 3710 Clamp-On Ground Resistance Tester

The AEMC 3710 Ground Resistance Tester simply clamps around the ground conductor or rod and measure the resistance to ground. The probe’s high sensitivity enables measurement of leakage current flowing to ground or circulating in ground loops down to 1 mA and neutral currents to 30 Arms. This feature provides additional information which is becoming vital as distribution ground networks carry higher levels of noise and harmonics which affect power quality. Specifications. Ground Resistance Measurement Range: Autoranging 1.0 to 1200 ohm. Ground Resistance Resolution: 0.1 ohm (1.0 to 50.0 ohm), 0.5 ohm (50.0 to 100.0 ohm), 1 ohm (100 to 200 ohm), 5 ohm (200 to 400 ohm), 10 ohm (400 to 600 ohm), 50 ohm (600 to 1200 ohm). Ground Resistance Accuracy: ± (1.5% + 0.1 ohm) (1.0 to 50.0 ohm), ± (2.0% + 0.5 ohm) (50.0 to 100.0 ohm), ± (3.0% + 1 ohm) (100 to 200 ohm), ± (6.0% + 5 ohm)(200 to 400 ohm), ± (10% + 10 ohm) (400 to 600 ohm). Resistance Measurement Frequency: 1.689 kHz. Ground or Leakage Current: Autoranging 1 mA to 30.00 Arms. Current Measurement Frequency: 47 to 800 Hz. Current Overload: OL displayed above 30 Arms.



 

Standard Calibration $245.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC 3710. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your AEMC 3710 CALIBRATION and/or AEMC 3710 Clamp-On Ground Resistance Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: