ROHDE & SCHWARZ FSIQ7 REPAIR and ROHDE & SCHWARZ FSIQ7 CALIBRATION

The ROHDE & SCHWARZ FSIQ7 is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the ROHDE & SCHWARZ FSIQ7. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ FSIQ7 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Analyzer?
Shop for Comparable Products on our
 used Signal Analyzer page

 
   ROHDE & SCHWARZ FSIQ7 (1119.5005.17)   Description / Specification:    
ROHDE & SCHWARZ FSIQ7 7 GHz Signal Analyzer

The Rohde & Schwarz FSIQ 7 (1119.5005.17) Signal Analyzer provides in a single unit comprehensive and easy-to-use measurement functions in the, frequency, time and modulation domain. In the frequency domain, the R&S FSIQ 7 measures intermodulation and harmonics with great accuracy. The high 3rd-order intercept point in conjunction with the extremely low noise floor yields an intermodulation-free dynamic range of >110 dB and ensures reliable performance of even sophisticated measurements. The excellent dynamic range and the optimized phase noise values make the R&S FSIQ an ideal tool for ACPR (adjacent- channel power ratio) measurements in all mobile radio systems and in particular for WCDMA. The maximum ACPR value for WCDMA in 4.096 MHz bandwidth is 75 dB and is already attained at -12 dBm input level. In the time domain, the R&S FSIQ 7 features all modern capabilities of burst analysis in TDMA systems; gate functions, trigger delay and integrated RF trigger in conjunction with a short sweep time of 1 µs ensure precise measurement of the timing characteristics of all main mobile radio systems. In the modulation domain, the integrated vector signal analyzer provides diverse measurements on signals with digital or analog modulation. The variety of settings that can be called simply at a keystroke covers 18 mobile radio standards from GSM, NADC, IS95 through to WCDMA. These convenient presettings make it superfluous for the user to spend valuable time in looking up specifications and go towards enhancing the measurement reliability. Specifications. Frequency range: 20 Hz to 7 GHz. Frequency resolution: 0.01 Hz. External reference frequency: 10 MHz or n x 1 MHz, n = 1 to 16. Frequency display: with marker or frequency counter. Resolution: 0.1 Hz to 10 kHz (dependent on span). Error limit (sweep time >3 x auto sweep time): ±(marker frequency x reference error + 0.5% x span + 10% x resolution bandwidth + ½ (last digit)). Frequency counter resolution: 0.1 Hz to 10 kHz (selectable). Display range for frequency axis: 0 Hz, 10 Hz to 7 GHz. Options. FSE-B10, Tracking Generator 7 GHz. FSE-B11, Tracking Generator 7 GHz with I/Q Modulator. FSE-B12, Switchable Attenuator for Tracking Generator. FSE-B13, 1 dB Attenuator. FSE-B16, Ethernet Interface. FSE-B17, 2nd IEC/IEEE-Bus Interface. FSE-B18, Removable Hard Disk. FSE-B19, 2nd Hard Disk for FSE-B18. FSIQ-B70, DSP and I/Q Memory Extension 2 x 512 k. FS-Z60, Harmonic Mixer 40 GHz to 60 GHz. FS-Z75, Harmonic Mixer 50 GHz to 75 GHz. FS-Z90, Harmonic Mixer 60 GHz to 90 GHz. FS-Z110, Harmonic Mixer 75 GHz to 110 GHz. FS-K3, Noise Measurement Software, Windows. FS-K4, Phase Noise Measurement Software. FSE-K10, GSM Application Firmware Mobile station. FSE-K11, GSM Application Firmware Base station. FSE-K20, EDGE Application Firmware Mobile station. FSE-K21, EDGE Application Firmware Base station. FSE-K30, 850 MHz Application Firmware Extension, GSM mobile test. FSE-K31, 850 MHz Application Firmware Extension, GSM BTS test. FSE-K71, Application Firmware for cdmaOne BTS code domain power measurement. FSE-K72, WCDMA/3GPP Application Firmware, BTS. FSE-K73, WCDMA/3GPP Application Firmware, Mobile (UE).



 

Standard Calibration $635.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ FSIQ7. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your ROHDE & SCHWARZ FSIQ7 REPAIR and/or ROHDE & SCHWARZ FSIQ7 7 GHz Signal Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: