ROHDE & SCHWARZ FSU26 CALIBRATION and ROHDE & SCHWARZ FSU26 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ FSU26 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   ROHDE & SCHWARZ FSU26 (1166.1660.26)   Description / Specification:    
ROHDE & SCHWARZ FSU26 26.5 GHz Spectrum Analyzer

The R&S FSU26 (1166.1660.26) 26.5 GHz Spectrum Analyzer handles a wide variety of measurement tasks in product development, an instrument must offer ample functionality and excellent performance in all areas of interest. Time-domain power in conjunction with channel or RRC filters turn the FSU3 into a fully-fledged channel power meter. It is just the right instrument for fast data transfer on the IEC/IEEE bus or an Ethernet LAN plus intelligent routines optimized for speed make for very short measurement times. Specifications. Frequency range: 20 Hz to 26.5 GHz. Reference frequency aging: 1 x 10^–7/year; with option FSU-B4: 3 x 10^–8/year. Phase noise: typ. –123 dBc (1 Hz) at 10 kHz from carrier. Residual FM: 1 Hz. Sweep time: 2.5 ms to 16000 s (Span >=10 Hz), 1 µs to 16000 s (Span 0 Hz (zero span)). Resolution bandwidth: 10 Hz to 50 MHz, FFT filter; 1 Hz to 30 kHz, channel filter, EMI bandwidth. Video bandwidth: 1 Hz to 10 MHz. Display range: displayed average noise level to +30 dBm. Displayed average noise level (10 Hz RBW): typ. –146 dBm (1 GHz), typ. –146 dBm (7 GHz), typ. –143 dBm (13 GHz). Displayed average noise level with preamplifier ON (FSU-B25), 1 GHz, 10 Hz RBW: <–152 dBm. Trace detectors: max peak, min peak, auto peak, sample, RMS, average, quasi-peak. Total measurement error, f < 3.6 GHz: 0.3 dB. Display linearity: 0.1 dB (0 dB to –70 dB). Options. FSU-B4 (1144.9000.02), Low-Aging OXCO. FSU-B9 (1142.8994.02), Tracking Generator, 100 kHz to 3.6 GHz. FSP-B10 (1129.7246.02), External Generator Control. FSU-B12 (1142.9349.02), Attenuator for Tracking Generator. FSU-B181 (1145.0242.04), Removable Hard Disk. FSU-B19 (1145.0394.04), Second Hard Disk for FSU-B18. FSU-B20 (1155.1606.08), Extended Environmental Specification. FSU-B21 (1157.1090.02), LO/IF Ports for External Mixers. FSU-B23 1157.0907.02), RF Preamplifier, 3.6 GHz to 26 GHz. FSU-B25 (1144.9298.02), Electronic Attenuator, 0 dB to 30 dB, and 20 dB preamplifier. FSU-B27 (1157.2000.02), Broadband FM Demodulator Output.



 

Standard Calibration $915.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ FSU26. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your ROHDE & SCHWARZ FSU26 CALIBRATION and/or ROHDE & SCHWARZ FSU26 26.5 GHz Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: