ROHDE & SCHWARZ NRVS CALIBRATION and ROHDE & SCHWARZ NRVS REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ NRVS Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Meter?
Shop for Comparable Products on our
 used RF Power Meter page

 
   ROHDE & SCHWARZ NRVS (1020.1809.02)   Description / Specification:    
ROHDE & SCHWARZ NRVS Single-Channel RF Power Meter

The Rohde & Schwarz NRVS Uses a range of measuring heads including thermal power sensors as well as highly sensitive diode power sensors, peak power sensors, probes and insertion units for voltage measurements. The NRVS covers a power span from 100 pW up to the kW range. In addition to the power sensors, all voltage probes of the URV5-Z series can be used. Operation of the power meter is to a great extent via selfexplanatory menus so that the user will hardly ever have to refer to the manual. For setting the instrument rapidly to a specific status, 20 complete setups can be stored. Measurement results, units and various items of information are displayed on a large 41/2-digit LC display in three steps of resolution. Specifications. Measurement functions: average power, pulse power, max. envelope power, DC and AC voltage (depending on measuring head). Frequency and level range: DC to 40 GHz, 100 pW to 30 W (depending on measuring head). Measuring heads: all voltage and power measuring heads NRV-Z and URV5-Z. Display: LCD for figures, units, user prompting and analog display. Resolution of digital display: 4 1/2 digits max., resolution adjustable in 3 modes; HIGH 12000 steps or 0.001 dB, MEDIUM 1200 steps or 0.01 dB, LOW 120 steps or 0.1 dB. Averaging filter: over 1 to 512 readings for reducing the display noise; manual or automatic setting depending on measurement range and resolution. DC control input for frequency response correction: BNC female, ±12 V, linear with selectable scale, input impedance 9 M-ohm, max. input voltage 50 V. DC output: BNC female, source impedance 1 kohm, output voltage (EMF) proportional to deflection of analog display, scale value: left 0 V, right +3 V, additional settling time 250 ms, error <=5 mV, ripple typ. 5 mV (Vpp).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ NRVS. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your ROHDE & SCHWARZ NRVS CALIBRATION and/or ROHDE & SCHWARZ NRVS Single-Channel RF Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: