ROHDE & SCHWARZ SML03 CALIBRATION and ROHDE & SCHWARZ SML03 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ SML03 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   ROHDE & SCHWARZ SML03 (1090.3000.13)   Description / Specification:    
ROHDE & SCHWARZ SML03 RF Signal Generator

The Rohde & Schwarz SML03 RF Signal Generator has an AF generator covering frequencies from 0.1 Hz to 1 MHz. Its signal can also be brought out for external applications at a separate connector. For two-tone modulation, you can operate the AF generator together with an external signal source. Option SML-B3 upgrades the R & S SML 03 for pulse modulation. In addition to a high-end pulse modulator, this option includes a pulse generator with enhanced features. All modulation modes are possible simultaneously. Only frequency and phase modulation exclude each other because they share circuitry in SML. You can set frequency with crystal resolution of 0.1 Hz. With option SML-B1 (OCXO reference oscillator) frequency accuracy fulfills even the most exacting requirements. The R&S SML 03 is fitted with an electronic attenuator to standard. Any number of levels may be set without causing wear, and setting times of 5 ms are typical. Using special frequency response correction, level error of <±0.5 dB up to 2 GHz and <±0.9 dB up to 3.3 GHz is obtained. With the R&S SML 03 the RF signal is generated by frequency division, resulting in excellent figures for SSB phase noise. Thanks to their low spurious FM of typically 0.5 Hz (at 1 GHz, 0.3 kHz to 3 kHz weighting bandwidth to CCITT), minimal SSB phase noise and high spurious suppression, these signal generators are ideal for all in-channel measurements on receivers. Specifications. Frequency range: 9 kHz to 3.3 GHz. Resolution: 0.1 Hz. Setting time: <10 ms. Harmonics: <–30 dBc. Subharmonics: none (f =1.1 GHz), <–50 dBc (f >1.1 GHz). Spurious: <–70 dBc (f =1.1 GHz), <–64 dBc (>1.1 GHz to 2.2 GHz), <–58 dBc (f >2.2 GHz). SSB phase noise: <–122 dBc (f = 1 GHz, 20 kHz carrier offset, 1 Hz bandwidth). Level: –140 dBm to +13 dBm (f >5 MHz to 3 GHz), –140 dBm to +11 dBm (f =5 MHz, f >3 GHz). Resolution: 0.1 dB. AM (3 dB bandwidth): 0 to 100 % (DC to 50 kHz). FM (3 dB bandwidth): deviation up to 4 MHz (DC to 500 kHz). phi M (3 dB bandwidth): deviation up to 40 rad (DC to 100 kHz), deviation up to 8 rad (DC to 500 kHz). AF generator: 0.1 Hz to 1 MHz.



 

Standard Calibration $770.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ SML03. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your ROHDE & SCHWARZ SML03 CALIBRATION and/or ROHDE & SCHWARZ SML03 RF Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province:
Zip/Postal Code:
Phone:*

Comment: