ROHDE & SCHWARZ SMP04 CALIBRATION and ROHDE & SCHWARZ SMP04 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ SMP04 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   ROHDE & SCHWARZ SMP04 (1035.5005.04)   Description / Specification:   Spec Sheet 
ROHDE & SCHWARZ SMP04 40 GHz Microwave Signal Generator

The R&S SMP04 (1035.5005.04) 40 GHz Microwave Signal Generator has been designed for high output power with AM, FM and optional phase modulation. High spectral purity is ensured by the use of YIG oscillators – up to 20 GHz without any frequency multiplying. The crystal reference built-in as standard ensures an accurate and low-drift output frequency. The SMP04 has extremely low SSB phase noise of <–105 dBc/Hz at 10 GHz (10 kHz from carrier) as well as nonharmonics of <–60/54 dBc up to/above 20 GHz. Functions qualifying the SMP04 for EMC applications include the trigger facility for step-by-step sweeping, marker outputs and, above all, the extension of the frequency range to 10 MHz (option SMP-B11). Specifications. Frequency Range: 2 GHz to 40 GHz. Resolution: 0.1 Hz. Setting time (to within <1x10^–6) after IEC-/IEEE-bus delimiter: <(11 ms + 5 ms/GHz). Phase offset: adjustable in 1° steps. Harmonics f <1.8 GHz: <–30 dBc (<+0 dBm). Nonharmonics at >10 kHz from carrier f <2 GHz: <–60 dBc typ. Maximum level: >+12 dBm (10MHz to <2GHz), >+10 dBm (2 GHz to <18 GHz), >+6 dBm (18 GHz to 20 GHz), >+11 dBm (20 GHz to 33 GHz), >+10 dBm (33 GHz to 40 GHz). Resolution: 0.1 dB or 0.01 dB. Output impedance: 50 ohm. Remote control: IEC625 (IEEE488). Options. SMP-B11 (1036.6240.02), Frequency Extension 0.01 GHz to 2 GHz. SMP-B12 (1036.5750.04), Pulse Modulator 2 GHz to 40 GHz. SMP-B13 (1036.7147.02), 0.01 GHz to 2 GHz. SMP-B14 (1036.7347.02), Pulse Generator. SMP-B17 (036.5550.02), RF Attenuator 40 GHz. SMP-B18 (1036.8920.02), Auxiliary Interface. SMP-B20 (1039.4503.02), Rear Connectors for RF, AF. SMP-B1 (1036.5109.02), OCXO Reference Oscillator. SM-B2 (1036.7947.02), LF Generator. SM-B5 (1036.8489.02), FM/phaseM Modulator.



 

Standard Calibration $730.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ SMP04. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your ROHDE & SCHWARZ SMP04 CALIBRATION and/or ROHDE & SCHWARZ SMP04 40 GHz Microwave Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: