SORENSEN DCS40-25E REPAIR and SORENSEN DCS40-25E CALIBRATION

 
Custom-Cal has a high success rate in the repair of the SORENSEN DCS40-25E. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SORENSEN DCS40-25E Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCS40-25E   Description / Specification:    
SORENSEN DCS40-25E 40V 25A Single Output DC Power Supply

The Sorensen DCS40-25E DC System Power Supply is designed to provide highly stable, continuously variable output voltage and current for a broad range of development, system, and burn-in applications. The DCS Series employs high frequency switching regulator technology to achieve high power density and small package size. An automatic crossover system enables the unit to switch operating modes in response to varying load requirements. Features. Simultaneous digital display of both voltage and current. Ten turn potentiometer voltage and current controls permit high resolution setting of the output voltage and current from zero to the rated output. Flexible output configuration: multiple units can be connected in parallel or series to provide increased current or voltage. Remote sensing to compensate for losses in power leads. Remote voltage, resistive, current limit and OVP programming with selectable programming constants. Optional IEEE-488 interface for complete remote programming and readback capability. Specifications. Output Voltage: 0 to 40 V. Output Current: 0 to 25 A. Output Power: 1000 W. Line Regulation Voltage: 40 mV. Line Regulation Current: 25 mA. Load Regulation Voltage: 40 mV. Load Regulation Current: 24 mA. Meter Accuracy Voltage: 0.5 V. Meter Accuracy Current: 0.35 A. OVP Adjustment Range: 2 to 44 V. Output Noise and Ripple (V) (20 Hz - 20 MHz): Rms 4 mV, p-p 60 mV. Stability Voltage: 20 mV. Stability Current: 12.5 mA. Temperature Coefficient Voltage: 8 mV/°C. Temperature Coefficient Current: 7.5 mA/°C. Maximum Remote Sense Line Drop Compensation/line: 4 V.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCS40-25E. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your SORENSEN DCS40-25E REPAIR and/or SORENSEN DCS40-25E 40V 25A Single Output DC Power Supply CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.