SORENSEN DCS60-50 CALIBRATION and SORENSEN DCS60-50 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SORENSEN DCS60-50 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCS60-50   Description / Specification:    
SORENSEN DCS60-50 60V 50A Single Output DC Power Supply

The Sorensen DCS60-50 programmable power supply incorporates current mode switching rates up to 100 kHz in high power density, low profile packages. Utilizing state-of-the-art technology and unique packaging techniques, the DCS60-50 provides continuous full output power in any volt/amp combination within the rated output voltage and current limits. Options include an internal IEEE-488/RS-232 interface and isolated analog programming of voltage or current. Specifications. Output Voltage: 0 to 60 V. Output Current: 0 to 50 A. Regulation Line and Load: 0.2%. Constant Voltage Mode Ripple (PARD): 20 mV rms. Constant Voltage Mode Resolution: 0.02%. Constant Voltage Mode Transient Response Time (Typ.): 500 µs. Temperature Coefficient Voltage (Typ.): 0.02 % C. Voltage Drift (Typ.): 0.05% V max. Constant Current Mode Regulation Line and Load: 0.2%. Constant Current Mode Ripple (PARD): 33 mA rms. Constant Current Mode Resolution (Typ.): 0.02%. Temperature Coefficient Current (Typ.): 0.03 % C. Current Drift (Typ.): 0.05% V max. Transient Response: < 1 ms recovery to 1 % band for 30% step load change (70- 100% or 100-70%) 500 µs typical. Stability: 0. 5% drift max over 8 hrs. with constant line, load and temperature, following 20 minute warm-up. Options. M51: Isolated programming control of either the output current or voltage using analog signals that can be biased up to 600V relative to the supply's return line. M85: Slave multichannel interface control.



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCS60-50. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your SORENSEN DCS60-50 CALIBRATION and/or SORENSEN DCS60-50 60V 50A Single Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: