STANFORD RESEARCH SYSTEMS PS310 CALIBRATION and STANFORD RESEARCH SYSTEMS PS310 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the STANFORD RESEARCH SYSTEMS PS310 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   STANFORD RESEARCH SYSTEMS PS310   Description / Specification:    
STANFORD RESEARCH SYSTEMS PS310 1250V 20mA Programmable Precision High Voltage Power Supply

The Stanford Research PS310 is a programmable precision high voltage power supply for use in laboratory or test applications. They feature reversible polarity, excellent regulation and low output voltage ripple. The digital displays provide accurate readings of voltage and current. Also, digital entry of the current and voltage provides accurate resettability. Output voltage can be set from either the front panel, the remote analog voltage, or over the optional GPIB interface. Voltage and current signals are also available for remote monitoring. Specifications. Output Voltage: 50 to ±1250 Volts. Maximum Output Current: 20 mA. Voltage Set Accuracy: 0.01% + 0.05% of full scale. Voltage Display Accuracy: V Set Accuracy ±1 Volt, typ ( ±2 Volt, max). Voltage Resolution: 1 Volt (set and display). Voltage Resettability: 1 Volt. Voltage Limit Range: 0 to 100% of full scale. Voltage Regulation: Line; 0.001% for ±10% line voltage change, Load; 0.005% for 100% load change, typ. Output Ripple: < 0.0015% of full scale, Vrms, typ. Current Limit and Trip Range: 0 to 105% of full scale. Current Set accuracy: 0.01% + 0.05% of full scale. Current Resolution: 10 µA. Current Display Accuracy: ±10 µA, typ ( ±20 µA, max). Stability: 0.01% per hour, < 0.03% per 8 hours. Temperature Drift: 50 ppm / °C, 0° to 50° C, typ. Protection: Arc and short circuit protected; programmable voltage and current limits and current trip.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the STANFORD RESEARCH SYSTEMS PS310. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your STANFORD RESEARCH SYSTEMS PS310 CALIBRATION and/or STANFORD RESEARCH SYSTEMS PS310 1250V 20mA Programmable Precision High Voltage Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: