TEKTRONIX 465 CALIBRATION and TEKTRONIX 465 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 465 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX 465   Description / Specification:    
TEKTRONIX 465 2 Ch 100 MHz Dual-Trace Oscilloscope

The Tektronix 465 is a 100 MHz Dual-Trace Oscilloscope. Specificatios. Bandwidth: Dc to 100 MHz, 3.5 ns. Deflection Factor: 5mV/div to 5V/div in 10 calibrated steps. Maximum Input Voltage: Dc Coupled; 250 V (dc + peak ac), 500 V (p-p ac at 1 kHz or less), Ac Coupled; 500 V (dc + peak ac), 500 V p-p (ac at 1 kHz or less). Time Base A: 0.05, us/div to 0.5 s/div in 22 calibrated steps (1-2-5 sequence). X10 MAG extends maximum sweep rate to 5 ns/div. Time Base B: 0.05, us/div to 50 ms/div in 19 calibrated steps (1-2-5 sequence). X10 MAG extends maximum sweep rate to 5 ns/div. Delay Time Range: 0.2 to 10X Delay Time/Div settings of 200 ns to 0.5 s (minimum delay time is 200 ns). Triggering: A Trigger Modes; Normal (sweep runs when triggered), Automatic (sweep free-runs in the absence of a triggering signal and for signals below 30 Hz), Single Sweep (sweep runs one time on the first triggering event after the reset selector is pressed). B Trigger Modes; B Runs After Delay Time (starts automatically at the end of the delay time), B Triggerable After Delay Time (runs when triggered), the B (delayed) sweep runs once, in each of these modes, following the A sweep delay time. X-Y Operation: Full-sensitivity X-Y(CH 1 Horiz, CH 2 Vert)-5 mV/ div to 5 V/div in 10 calibrated steps, accurate within 4% . Bandwidth is dc to at least 4 MHz. Phase difference between amplifiers is 3° or less from dc to 50 kHz. Crt: 5-inch rectangular tube; 8 x 10-cm display area.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 465. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your TEKTRONIX 465 CALIBRATION and/or TEKTRONIX 465 2 Ch 100 MHz Dual-Trace Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: