A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 466 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX 466   Description / Specification:    
TEKTRONIX 466 2 Ch 100 MHz Oscilloscope

The Tektronix 466 100 MHz Dual-Trace Oscilloscope specifications. Bandwidth: Dc to 100 MHz, <=3.5 ns. Deflection Factor: 5mV/div to 5V/div in 10 calibrated steps, (1-2-5 sequence); accurate within 3%; continuously variable between steps and to approximately 12.5 volts/div. Maximum Input Voltage: Dc Coupled; 250 V (dc + peak ac), 500 V (p-p ac at 1 kHz or less), Ac Coupled; 500 V (dc + peak ac), 500 V p-p (ac at 1 kHz or less). Time Base A: 0.05, us/div to 0.5 s/div in 22 calibrated steps (1-2-5 sequence). X10 MAG extends maximum sweep rate to 5 ns/div. Time Base B: 0.05, us/div to 50 ms/div in 19 calibrated steps (1-2-5 sequence). X10 MAG extends maximum sweep rate to 5 ns/div. Calibrated Sweep Delay: Continuously variable from 0.2 us to at least 5 seconds. Triggering: A Trigger Modes; Normal (sweep runs when triggered), Automatic (sweep free-runs in the absence of a triggering signal), Single Sweep (sweep runs one time on the first triggering event after the reset selector is pressed). B Trigger Modes; B Runs After Delay Time (starts automatically at the end of the delay time), B Triggerable After Delay Time (runs when triggered), the B (delayed) sweep runs once, in each of these modes, following the A sweep delay time. X-Y Operation: Full-sensitivity X-Y (CH 1 Horiz, CH 2 Vert)- 5 mV/div to 5 V/div in 10 calibrated steps, accurate within 4%. Bandwidth is dc to at least 4 MHz. CRT: Internal graticule with variable illumination; 8 x 10 div, 0.9 cm/div (normal) ; 8 x 10 div, 0.45 cm/div (reduced scan).



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 466. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX 466 CALIBRATION and/or TEKTRONIX 466 2 Ch 100 MHz Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: