TEKTRONIX 2236 CALIBRATION and TEKTRONIX 2236 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 2236 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX 2236   Description / Specification:    
TEKTRONIX 2236 2 Ch 100 MHz Dual Trace Oscilloscope

The Tektronix 2236 100 MHz 2-Ch Dual Trace Oscilloscope has a counter/ timer/ DMM, integrated into the scope's vertical, horizontal and trigger systems. The Tek 2236 provides easy, accurate, and versatile measurements through microprocessor-driven waveform analysis. Autoranged and autoaveraged counter/timer measurements are made on the signal triggering the A sweep, or in gated modes on the signal triggering the B sweep. Autoranged DMM measurements are made through floating DMM side inputs and up-range at 5000 counts. Channel 1 voltage measurements made on Channel 1 signal include: dc, relative dc, relative and true ac RMS voltage. Self-testing includes power-on and user interactive routines. Characteristics. Vertical System: Bandwidth (- 3dB) and Rise Time: 100 MHz and 3.5 ns, derated to 90 MHz at 2 mV/div and outside 0°C to +35°C. Bandwidth Limit: 20 MHz ± 10%. Deflection Factor: 2 mV to 5 V/div at ±2%. Step Response Aberrations: +4%, -4%, 4% p-p (5 mV to 0.5 V/div), +5%, -5%, 5% p-p (2 mV/div). Display Modes: CH 1, CH 2, CH 2 Invert, Add, Alternate, Chop (500 kHz). Common-Mode Rejection Ratio: At least 10:1 at 50 MHz for signals of 6 div or less. Maximum Input Voltage (Ac and Dc Coupled): 400 V (dc + peak ac) or 800 V (p-p to 10kHz). Channel 1/ Channel 2 Isolation: 100:1 at 50 MHz. Horizontal System: Sweep Rate: A Time Base: 0.05 /uS to 0.5 s/div in 1-2-5 sequence. 10X Mag: 5 ns/div. B Time Base: 0.05 /uS to 50 ms/div in 1-2-5 sequence. 10X Mag: 5 ns/div. Sweep Linearity: ± 5% over any two of center eight divisions. Delay Time Range: Continuously variable with 10-turn control from < 0.5 +300 ns to > 10div. Display: Monochrome CRT - 8 cm x 10 cm.



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 2236. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your TEKTRONIX 2236 CALIBRATION and/or TEKTRONIX 2236 2 Ch 100 MHz Dual Trace Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: