TEKTRONIX 11801C CALIBRATION and TEKTRONIX 11801C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 11801C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX 11801C   Description / Specification:    
TEKTRONIX 11801C Digital Sampling Oscilloscope Mainframe

DC To 50 GHz Digital Sampling Oscilloscope. Eight Channels(accepts up to 4 dual-channel sampling heads), Expandable to 136 (with SM-11 multi-channel units). Rise Time/Bandwidth: Determined by the sampling head used. Vertical Resolution: 8 bits full screen (78 uV LSB at 2 mV/div deflection factor). Amplifier Gain Accuracy: ± 1 % of all settings. Deflection Factors - 2 to 255 mV/div in 1 mV/div increments. Offset Range: ±2 V. Main and Window Time Base: 1 ps/div to 5 ms/ div, settable in 1-2-5 sequence or in 1 ps increments. Time Interval Accuracy: 8 ps + 0.01 % x (interval) + 0.001% x (position), guaranteed; 4 ps + 0.004% x (interval) + 0.0004% x (position), typical, where interval >= 1 ns; 2.5 ps + 0.0004% x (position), typical, where interval = 100 ps; 1 ps + 0.0004% x (position), typical, where intervals < 10 ps. Record Length: 512, 1024, 2048, 4096 and 5120 samples. Maximum Sampling Rate: 200 ks/s. Trigger Bandwidth: Direct 4 GHz typical, Prescaled 12.5 GHz typical. Trigger Sensitivity: Direct DC to 4 GHz: 50 mV typical. Prescaled 2 to 10 GHz: 500 mV, 10 to 12.5 GHz: 800 mV typical. Internal Clock: 100 kHz (drives TDR, Internal Clock Output and Calibrator). Trigger Level Range: ±1.0 V (± 10 V with 10X trigger attenuator activated). CRT - 9 in. diagonal. magnetic deflection, vertical raster scan orientation. Color.



 

Standard Calibration $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 11801C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX 11801C CALIBRATION and/or TEKTRONIX 11801C Digital Sampling Oscilloscope Mainframe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: