A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 11801C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX 11801C   Description / Specification:    
TEKTRONIX 11801C Digital Sampling Oscilloscope Mainframe

DC To 50 GHz Digital Sampling Oscilloscope. Eight Channels(accepts up to 4 dual-channel sampling heads), Expandable to 136 (with SM-11 multi-channel units). Rise Time/Bandwidth: Determined by the sampling head used. Vertical Resolution: 8 bits full screen (78 uV LSB at 2 mV/div deflection factor). Amplifier Gain Accuracy: ± 1 % of all settings. Deflection Factors - 2 to 255 mV/div in 1 mV/div increments. Offset Range: ±2 V. Main and Window Time Base: 1 ps/div to 5 ms/ div, settable in 1-2-5 sequence or in 1 ps increments. Time Interval Accuracy: 8 ps + 0.01 % x (interval) + 0.001% x (position), guaranteed; 4 ps + 0.004% x (interval) + 0.0004% x (position), typical, where interval >= 1 ns; 2.5 ps + 0.0004% x (position), typical, where interval = 100 ps; 1 ps + 0.0004% x (position), typical, where intervals < 10 ps. Record Length: 512, 1024, 2048, 4096 and 5120 samples. Maximum Sampling Rate: 200 ks/s. Trigger Bandwidth: Direct 4 GHz typical, Prescaled 12.5 GHz typical. Trigger Sensitivity: Direct DC to 4 GHz: 50 mV typical. Prescaled 2 to 10 GHz: 500 mV, 10 to 12.5 GHz: 800 mV typical. Internal Clock: 100 kHz (drives TDR, Internal Clock Output and Calibrator). Trigger Level Range: ±1.0 V (± 10 V with 10X trigger attenuator activated). CRT - 9 in. diagonal. magnetic deflection, vertical raster scan orientation. Color.



 

Standard Calibration $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 11801C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your TEKTRONIX 11801C CALIBRATION and/or TEKTRONIX 11801C Digital Sampling Oscilloscope Mainframe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: