TEKTRONIX DPO2014 CALIBRATION and TEKTRONIX DPO2014 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DPO2014 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX DPO2014   Description / Specification:    
TEKTRONIX DPO2014 4 Ch 100 MHz Digital Phosphor Oscilloscope

Tektronix DPO2014 100 MHz digital phosphor oscilloscope, 4 channel. Maximum Sample Rate: 1.0 GS/s. Calculated Rise Time: 3.5 ns. Hardware Bandwidth Limits: 20 MHz. Input Coupling: AC, DC, GND. Input Impedance: 1 M-Ohm ±2%, 11.5 pF ±2 pF. Input Sensitivity Range: 2 mV/div to 5 V/div. Vertical Resolution 8 bits. Maximum Input Voltage, 1 M-Ohm: 300 VRMS with peaks <= ±450 V. DC Gain Accuracy (with offset set to 0 V): ±3% for 10 mV/div to 5 V/div, ±4% for 2 mV/div to 5 mV/div. Horizontal System Analog Channels; Maximum Sample Rate (all channels): 1 GS/s. Maximum Record Length (all channels): 1 Mpoints. Maximum Duration of Time Captured at Highest Sample Rate (all channels): 1 ms. Time-base Range (s/div) 4 ns to 100 s. Time-base Delay Time Range: -10 divisions to 5000 s. Channel-to-Channel Deskew Range: ±100 ns. Time-base Accuracy: ±25 ppm. Display Type: 7 in. (180 mm) liquid crystal TFT color display.



 

Standard Calibration $190.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DPO2014. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX DPO2014 CALIBRATION and/or TEKTRONIX DPO2014 4 Ch 100 MHz Digital Phosphor Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: