A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DPO3034 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX DPO3034   Description / Specification:   Spec Sheet 
TEKTRONIX DPO3034 4 Ch 300 MHz Digital Phosphor Oscilloscope

300 MHz digital phosphor oscilloscope, 4 channel. Maximum Sample Rate: 1.0 GS/s. Calculated Rise Time: 1.17 ns. Hardware Bandwidth Limits: 20, 150 MHz. Input Coupling: AC, DC, GND. Input Impedance: 1 M-Ohm ±1%, 75 ohm ±1%, 50 ohm ±1%. Input Sensitivity Range 1 M-ohm: 1 mV/div to 10 V/div. Input Sensitivity Range, 75 ohm, 50 ohm: 1 mV/div to 1 V/div. Vertical Resolution: 8 bits(11 bits with Hi Res). Maximum Input Voltage, 1 M-Ohm: 300 VRMS with peaks <= ±450 V. DC Gain Accuracy: ±1.5% for 5 mV/div and above, ±2.0% for 2 mV/div, ±2.5% for 1 mV/div. Horizontal System Analog Channels; Maximum Sample Rate (Main, all channels): 500 MS/s (2 ns resolution). Maximum Record Length (Main, all channels): 5 Mpoints. Maximum Duration of Time Captured at Highest Sample Rate (all channels): 2 ms. Time-base Range (s/div): 1 ns to 1000 s. Time-base Delay Time Range: -10 divisions to 5000 s. Channel-to-Channel Deskew Range: ±100 ns. Time-base Accuracy: ±10 ppm over any >=1 ms interval. Display Type: 9 in. (228.6 mm) wide format liquid crystal TFT color display.



 

Standard Calibration $190.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DPO3034. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your TEKTRONIX DPO3034 CALIBRATION and/or TEKTRONIX DPO3034 4 Ch 300 MHz Digital Phosphor Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: