TEKTRONIX 5A48 CALIBRATION and TEKTRONIX 5A48 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 5A48 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   TEKTRONIX 5A48   Description / Specification:    
TEKTRONIX 5A48 Dual Trace Amplifier Plug-in

Dual-trace plug-in amplifier for use only in the 5223 and the 5400 Series mainframes. Bandwidth - Dc Coupled: Dc to at least 50 MHz at 5 mV/div to 10 V/div, dc to at least 25 MHz at 1 mV/div and 2 mV/div (3 dB down). Ac coupled: 10 Hz or less (1 Hz with 10X probe) at all deflection factors (3 dB down). Deflection Factors - Calibrated: 1 mV/div to 10 V/div in a 1-2-5 sequence. Accuracy: < 5% at 1 mV/div and 2 mV/div; < 3% from 5 mV/div to 10 V/div from + 15°C to +35°C; < 4% from 5 mV/div to 10 V/div from 0°C to +50°C. Uncalibrated: Variable is continuous between steps to at least 25 V/div. Input R and C - 1 M-ohm within 1 % paralleled by ~24 pF. Maximum Input Voltage - Dc Coupled: 250 V (dc + peak ac. Ac Coupled: 500 V (dc + peak ac). Ac Component: 500 V p-p maximum, 1 kHz or less. Stability - < 0.3 mV vertical shift in anyone minute after one hour warm-up, ambient temperature and line voltage held constant. < 0. 2 mV/°C vertical shift with line voltage held constant. Display Modes - Channel 1 only, Channel 2 only (normal or inverted), Dual trace, Added, Alternated, Chopped (determined by time base plug-in horizontal compartment). Internal Trigger Source: Selectable from Channell or Channel 2. Rise Time - 7 ns or less (5 mV/div to 10 V/div), 14 ns or less (1 mV/div and 2 mV/div).



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 5A48. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX 5A48 CALIBRATION and/or TEKTRONIX 5A48 Dual Trace Amplifier Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: