TEKTRONIX 7A29 CALIBRATION and TEKTRONIX 7A29 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 7A29 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   TEKTRONIX 7A29   Description / Specification:    
TEKTRONIX 7A29 Wideband Single-trace Amplifier Plug-in

The Tektronix 7A29 is a Dc to 1 GHz, High-performance, wide-bandwidth, single-trace amplifier, is designed primarily for use with the7100, 7700-, 7800-, and 7900-Series Mainframes. Bandwidth is constant over the entire range of calibrated deflection sensitivities of 10 mV to 1 Vldiv. Input impedance is 50 ohm. Manually resettable input-protection circuitry protects the input against most common overloads. Polarity of the display is selectable by a front-panel switch. An optional variable delay line (front-panel adjustable) permits matching the transit time of two 7A29s and/or probes to better than 10 ps. The 7A29 has a 10 mV/ div to 1 V/ div vertical sensitivity. Deflection Factor-10 mV/div to 1 V/div in 7 calibrated steps (1-2-5 sequence). Accuracy is within 2% with gain adjusted at 0.1 V/div. Uncalibrated variable is continuous between steps to at least 2.5 V/div. Input R - 50 ohm. Option 04, Variable Signal Delay - Permits matching the transit time of two preamps and probes to better than 10 ps, Range is 1 ns. Max Input- 10 V RMS or 1 W-second pulses not exceeding 50 V peak in dc coupled mode. 100 V dc additional in ac coupled mode.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 7A29. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX 7A29 CALIBRATION and/or TEKTRONIX 7A29 Wideband Single-trace Amplifier Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: