TEKTRONIX 7B92A CALIBRATION and TEKTRONIX 7B92A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 7B92A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   TEKTRONIX 7B92A   Description / Specification:    
TEKTRONIX 7B92A Dual Time Base Plug-in

The Tektronix 7B92A Dual Time Base is recommended for use only in the 7800 and 7900 Series Mainframes. Features: 0.5 ns/div to 0.2 s/div Calibrated Time Base. Triggering to 500 MHz. Alternate Display of Intensified. Delaying and Delayed Sweeps. Contrast Regulation between. Delaying and Delayed Sweeps. Sweep Rate - 0.2 s/div to 10 ns/div in 23 calibrated steps (1-2-5 sequence) . An uncalibrated variable rate is continuous between steps, and extends sweep rate to at least 0.5 s/div. The VARIABLE control is internally switchable between delaying and delayed sweeps. Delay Time Multiplier Range - 0 to 9.8 times the DLY TIME/DIV setting from 0.2 s/div to 10 ns/div (0 to 1.96 seconds). Internal Trigger Jitter - 50 ps or less at 500 MHz. External Trigger Input - Selectable 50 ohm or 1 M-ohm inputs (1 M-ohm is paralleled by approx 20 pF). Max safe input is 250 V (dc + peak ac) for 1 M-ohm input, and 1 W average for 50 ohm input. Range of trigger level is at least ±3.5 V in EXT, and at least ±35 V in EXT + 10.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 7B92A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your TEKTRONIX 7B92A CALIBRATION and/or TEKTRONIX 7B92A Dual Time Base Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: