TEKTRONIX 7B92A CALIBRATION and TEKTRONIX 7B92A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 7B92A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   TEKTRONIX 7B92A   Description / Specification:    
TEKTRONIX 7B92A Dual Time Base Plug-in

The Tektronix 7B92A Dual Time Base is recommended for use only in the 7800 and 7900 Series Mainframes. Features: 0.5 ns/div to 0.2 s/div Calibrated Time Base. Triggering to 500 MHz. Alternate Display of Intensified. Delaying and Delayed Sweeps. Contrast Regulation between. Delaying and Delayed Sweeps. Sweep Rate - 0.2 s/div to 10 ns/div in 23 calibrated steps (1-2-5 sequence) . An uncalibrated variable rate is continuous between steps, and extends sweep rate to at least 0.5 s/div. The VARIABLE control is internally switchable between delaying and delayed sweeps. Delay Time Multiplier Range - 0 to 9.8 times the DLY TIME/DIV setting from 0.2 s/div to 10 ns/div (0 to 1.96 seconds). Internal Trigger Jitter - 50 ps or less at 500 MHz. External Trigger Input - Selectable 50 ohm or 1 M-ohm inputs (1 M-ohm is paralleled by approx 20 pF). Max safe input is 250 V (dc + peak ac) for 1 M-ohm input, and 1 W average for 50 ohm input. Range of trigger level is at least ±3.5 V in EXT, and at least ±35 V in EXT + 10.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 7B92A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX 7B92A CALIBRATION and/or TEKTRONIX 7B92A Dual Time Base Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: