TEKTRONIX DC5010 CALIBRATION and TEKTRONIX DC5010 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DC5010 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   TEKTRONIX DC5010   Description / Specification:    
TEKTRONIX DC5010 Programmable Universal Counter / Timer Plug-in

The Tektronix DC 5010 Programmable Universal Counter / Timer features reciprocal frequency to 350 MHz, period, ratio, events B during A measurements, and time A to B. The powerful reciprocal technique provides high resolution of low frequency signals much faster than conventional counting techniques. The pseudo-random, phase-modulated time base provides increased accuracy by eliminating synchronous errors in the time interval and width averaging modes. Auto trigger senses the applied signal and sets trigger levels to the optimum points. In the DC 5010, trigger levels, the minimum and maximum signal voltage levels, and the trigger voltage are available over the GPIB, and can be viewed on the 9-digit display. Channel A and Channel B Input; Frequency Range - 50 ohm termination: >0 to >= 350 MHz DC coupled. 100 kHz to >= 350 MHz AC coupled. 1 M-ohm termination > 0 to >= 300 MHz DC coupled. 16 Hz to >= 300 MHz AC coupled. Sensitivity - 50 ohm termination DC: <= 25 mV RMS sinewave to 350 MHz <= 70 mV p-p pulse 1 M-ohm termination. DC/AC <= 25 mV RMS to 200 MHz. 42 mV RMS to 300 MHz. Attenuation Selectable - 1X, 5X. Impedance - 1 M-ohm paralleled by 23 pf ±2.2 pF (10%) or 50 ohm ±3% DC. Dynamic Range - 70 mV p-p to 4 V p-p (x attenuation). Trigger Level Range - >= + 2 V to <= - 2 V with 4 mV resolution (X1). <= ±10 V to <= -10 V with 20 mV resolution (X5). Trigger Level Accuracy - ±1 % of F.S. trigger level range, plus ±2% of reading for a DC input V, ±40 mV X Attenuator. Autotrigger Frequency Range - 10Hz to <= 350 MHz. Independent Controls - Slope, Attenuation 1X / 5X, Couple AC/DC, Impedance 1 M-ohm / 50 ohm. Frequency A Range: <= 36 uHz to >= 350 MHz. Accuracy Resolution: ±(Time Base Error x Frequency A). Rise / fall A Range - 5.0 ns to 7.6 hrs.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DC5010. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your TEKTRONIX DC5010 CALIBRATION and/or TEKTRONIX DC5010 Programmable Universal Counter / Timer Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: