TEKTRONIX DC509 CALIBRATION and TEKTRONIX DC509 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DC509 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   TEKTRONIX DC509   Description / Specification:    
TEKTRONIX DC509 Universal Counter / Timer Plug-in

The Tektronix DC 509 single-width Universal Counter / Timer provides all of the measurement functions of the higher performance DC 5010/ DC 510 except rise time/fall time, null, and totalize A ± B. The powerful reciprocal-frequency measurement technique allows up to eight digits of resolution of low-frequency signals in one second or less of measurement time. The DC 509 has the same automatic averaging feature as the DC 5010/ DC 510; selected averaging of up to 108 events provides usable time-interval resolution of 5 ps. Channel A and Channel B Input; Frequency Range - >0 to >= 135 MHz DC coupled. <= 10 Hz to >= 135 MHz AC coupled. Sensitivity - <= 20 mV RMS (56.6 mV p-p) to >= 100 MHz, 40 mV RMS (113 mVp-p) from 100 MHz to >= 135 MHz, 115 mV p-p at minimum, pulse width of 3 ns. Attenuation Selectable - 1X, 5X. Impedance - 1 M-ohm ±2% paralleled by <= 30 pF. Trigger Level Range - +3.200 to -3.175 V with 25 mV resolution (X1), + 16 to -15.875 V with 125 mV resolution (x5). Trigger Level Accuracy - ±15 mV ±40 uV/°C referenced to 25°C. Dynamic Range - 3.2 <= input voltage <= +3.2 . X1: Vin p-p <= 3 V; X5: Vp-p 15 Vin (for input signal risetime p-p <= 3 V; X5: Vp-p 15 Vin); (for input signal risetimes <= 5 ns). Autotrigger Frequency Range - Sensitivity <= 125 mV p-p x attenuation; <= 20 Hz to >= 100 MHz. Range: ±3.2 V x attenuation. Resolution: 25 mV x attenuation. Independent Controls - Slope ±, attenuation 1X / 5X, Couple AC/DC, Source Internal/External. Frequency A Range: <= 100 uHz to >= 135 MHz. Accuracy Resolution: ±(Time Base Error x Frequency A). Rise / fall A Range - 7.4 ns to 3.05 hrs.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DC509. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your TEKTRONIX DC509 CALIBRATION and/or TEKTRONIX DC509 Universal Counter / Timer Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: