TEKTRONIX DC509 CALIBRATION and TEKTRONIX DC509 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DC509 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   TEKTRONIX DC509   Description / Specification:    
TEKTRONIX DC509 Universal Counter / Timer Plug-in

The Tektronix DC 509 single-width Universal Counter / Timer provides all of the measurement functions of the higher performance DC 5010/ DC 510 except rise time/fall time, null, and totalize A ± B. The powerful reciprocal-frequency measurement technique allows up to eight digits of resolution of low-frequency signals in one second or less of measurement time. The DC 509 has the same automatic averaging feature as the DC 5010/ DC 510; selected averaging of up to 108 events provides usable time-interval resolution of 5 ps. Channel A and Channel B Input; Frequency Range - >0 to >= 135 MHz DC coupled. <= 10 Hz to >= 135 MHz AC coupled. Sensitivity - <= 20 mV RMS (56.6 mV p-p) to >= 100 MHz, 40 mV RMS (113 mVp-p) from 100 MHz to >= 135 MHz, 115 mV p-p at minimum, pulse width of 3 ns. Attenuation Selectable - 1X, 5X. Impedance - 1 M-ohm ±2% paralleled by <= 30 pF. Trigger Level Range - +3.200 to -3.175 V with 25 mV resolution (X1), + 16 to -15.875 V with 125 mV resolution (x5). Trigger Level Accuracy - ±15 mV ±40 uV/°C referenced to 25°C. Dynamic Range - 3.2 <= input voltage <= +3.2 . X1: Vin p-p <= 3 V; X5: Vp-p 15 Vin (for input signal risetime p-p <= 3 V; X5: Vp-p 15 Vin); (for input signal risetimes <= 5 ns). Autotrigger Frequency Range - Sensitivity <= 125 mV p-p x attenuation; <= 20 Hz to >= 100 MHz. Range: ±3.2 V x attenuation. Resolution: 25 mV x attenuation. Independent Controls - Slope ±, attenuation 1X / 5X, Couple AC/DC, Source Internal/External. Frequency A Range: <= 100 uHz to >= 135 MHz. Accuracy Resolution: ±(Time Base Error x Frequency A). Rise / fall A Range - 7.4 ns to 3.05 hrs.



 

Standard Calibration $345.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DC509. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your TEKTRONIX DC509 CALIBRATION and/or TEKTRONIX DC509 Universal Counter / Timer Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: