TEKTRONIX DPO4054 REPAIR and TEKTRONIX DPO4054 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX DPO4054. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DPO4054 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX DPO4054   Description / Specification:   Spec Sheet 
TEKTRONIX DPO4054 4 Ch 500 MHz Digital Phosphor Oscilloscope

The Tektronix DPO4054 500 MHz digital phosphor oscilloscope (DPO) delivers the performance you need to visualize even your most demanding signals. It offers a minimum of 5x oversampling on all channels and sin(x)/x interpolation standard. The standard 10 M record length on all channels enables you to capture long windows of signal activity while maintaining fine timing resolution.

Vertical System Analog Channels
Input Channels: 4.
Analog Bandwidth (-3 dB) 5 mV/div -1 V/div: 500 MHz.
Calculated Rise Time 5 mV/div (typical): 700 ps.
Hardware Bandwidth Limits: 20 MHz or 250 MHz.
Input Coupling: AC, DC, GND.
Input Impedance 1 MΩ: ±1%, 50 Ω ±1%.
Input Sensitivity, 1 MΩ: 1 mV/div to 10 V/div.
Input Sensitivity, 50 Ω: 1 mV/div to 1 V/div.
Vertical Resolution: 8 bits (11 bits with Hi Res).
Max Input Voltage, 1 MΩ: 250 VRMS with peaks ≤ ±400 V.
Max Input Voltage, 50 Ω: 5 VRMS with peaks < ±20 V.
DC Gain Accuracy: ±1.5% with offset set to 0 V.
Channel-to-Channel Isolation: ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth for any two channels having equal volts/div settings.

Horizontal System Analog Channels
Maximum Sample Rate (All channels): 2.5 GS/s.
Maximum Record Length (All channels): 10M points.
Maximum Duration at Highest Sample Rate (All channels): 4 ms.
Time Base Range: 1 ns to 1,000 s.
Time Base Delay Time Range: -10 divisions to 5000 s.
Channel-to-Channel Deskew Range: ±100 ns.
Time Base Accuracy: ±5 ppm over any ≥1 ms interval.

Trigger System
Main Trigger Modes: Auto, Normal, and Single.
Trigger Coupling: DC, HF reject (attenuates >50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity).
Sensitivity, Internal DC Coupled: 0.4 div DC to 50 MHz increasing to 1 div at rated bandwidth.

Display Type: 10.4 in. (264 mm) XGA Color Display.



 

Standard Calibration $190.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DPO4054. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your TEKTRONIX DPO4054 REPAIR and/or TEKTRONIX DPO4054 4 Ch 500 MHz Digital Phosphor Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: