TEKTRONIX FG503 CALIBRATION and TEKTRONIX FG503 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX FG503 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   TEKTRONIX FG503   Description / Specification:    
TEKTRONIX FG503 Function Generator Plug-In

The Tektronix FG 503 Function Generator provides high-quality low-distortion sine, square, and triangle waveforms. Six decade frequency multiple steps, a custom position for user-determined frequency multiplication, a dial calibrated from 1.0 to 30 (uncalibrated from 0.1 to 1.0), and a frequency vernier control work together to select frequencies in overlapping ranges from 1 Hz to 3 MHz. The output frequency can be swept over a 1000:1 ratio by an external voltage. Output amplitude and offset controls are provided. A trigger output is available for controlling external devices or equipment. Amplitude up to 10 V peak-to peak can be developed across a 50-ohmload (20 V peak-to-peak open circuit). Selectable offset up to 3.75 V dc across 50 ohm (7 .5 V dc open circuit) is also featured. Frequency Range with var. symmetry: 1 Hz to 3 MHz (0.01 Hz to 5 MHz usable). Dial Accuracy % of full scale: <=5. Amplitude open circuit: 20 Vpp. Offset open circuit: ±7.5 V dc. Peak Signal + Offset open circuit: ±15 V dc. Output Impedance: 50 ohms. Amplitude Flatness 10-kHz ref, 50-ohm load): Sine ±0.5 dB, 20 Hz to 20 kHz; ±1.5 dB, 0.1 to 3 MHz; Triangle ±1 dB ref to Sine Wave; Square ±1 dB ref to Sine Wave. Square-Wave Response: <= 60-ns rise/fall; <=3% p-p aberrations.



 

Standard Calibration $450.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX FG503. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your TEKTRONIX FG503 CALIBRATION and/or TEKTRONIX FG503 Function Generator Plug-In REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: