TEKTRONIX P6245 CALIBRATION and TEKTRONIX P6245 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX P6245 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Accessory?
Shop for Comparable Products on our
 used Oscilloscope Accessory page

 
   TEKTRONIX P6245   Description / Specification:    
TEKTRONIX P6245 1.5 GHz, 10X Active FET Probe

The Tektronix P6245 is a 1.5 GHz, 10X active FET probe with less than 1 pF input capacitance. Its low input capacitance and high input resistance minimize circuit loading over a wide bandwidth range. The P6245’s small profile and low-mass head makes probing crowded circuits by hand fast and easy. It is powered through a TEKPROBE interface between the probe’s compensation box and the oscilloscope.
Specifications.

Analog Bandwidth (system): 1 GHz.
DC Attenuation Accuracy (probe only): 10:1 ±2%.
Output Zero: ±5 mV or less at output of probe, ±50 mV or less displayed on screen with TEKPROBE interface.
Rise Time (probe only): 267 ps on ≥10 GHz oscilloscope.

Characteristics.
Analog Bandwidth (probe only): 1.5 GHz on ≥10 GHz oscilloscope.
Linear Input Dynamic Range: - 8 V to + 8 V (Equivalent to - 0.8 V to + 0.8 at the output of the probe.)
Linearity: ± 4% or less of dynamic range.
Non-Destructive Input Voltage Range: - 15 V to + 15 V (DC + peak AC).
Input Resistance: 1 MΩ at DC.
Input Capacitance: ≤1.0 pF.
Offset Range: -10 V to +10 V.
DC Offset Drift: 100 uV/°C or less at output of probe.
Delay Time: 5.3 ns ±0.2 ns.



 

Standard Calibration $55.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX P6245. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your TEKTRONIX P6245 CALIBRATION and/or TEKTRONIX P6245 1.5 GHz, 10X Active FET Probe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: