TEKTRONIX TDS2002 CALIBRATION and TEKTRONIX TDS2002 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS2002 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS2002 (TDS-2002)   Description / Specification:   Spec Sheet 
TEKTRONIX TDS2002 2 Ch 60 MHz Digital Storage Oscilloscope

60 MHz Digital Storage Oscilloscope, Two Channel. Sample Rate on Each Channel: 1.0 GS/s. Maximum Record Length: 2.5K points. Vertical Resolution: 8–bits. Vertical Sensitivity: 2 mV to 5 V/div. Vertical Accuracy: ±3%. Max Input Voltage: 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vpk-pk AC at 3 MHz and above. Position Range 2 mV to 200 mV/div ±2 V; >200 mV to 5 V/div ±50 V. Bandwidth Limit: 20 MHz. Input Coupling: AC, DC, GND. Input Impedance Selections: 1 megaohm in parallel with 20 pF. Time Base Range: 5 ns - 50 s/div. Accuracy: 50 ppm. Acquisition Modes; Peak Detect – High frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) using acquisition hardware at all time/div settings from 5 µs/div to 50 s/div. Sample – Sample data only. Average – Waveform averaged, selectable: 4, 16, 64, 128. Single Sequence – Use the Single Sequence button to capture a single triggered acquisition sequence at a time. Trigger Modes – Auto, Normal, Single Sequence. Trigger Types; Edge (rising or falling) – Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject. Video – Trigger on all lines or individual line, odd/even or all fields from composite video or broadcast standards (NTSC, PAL, SECAM). Pulse Width (or Glitch) – Trigger on a pulse width less than, greater than, equal to, or not equal to a selectable time limit ranging from 33 ns to 10 s. Trigger Source: CH1, CH2, Ext, Ext/5, AC Line. 1/4 VGA, passive color LCD with color on black background with adjustable multi-level contrast.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS2002. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX TDS2002 CALIBRATION and/or TEKTRONIX TDS2002 2 Ch 60 MHz Digital Storage Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: