Custom-Cal has a high success rate in the repair of the TEKTRONIX TDS 220. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS 220 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS 220 (TDS220)   Description / Specification:    
TEKTRONIX TDS 220 2 Ch 100 MHz Digital Storage Oscilloscope

100 MHz Digital Storage Oscilloscope. Total Channels: 2. Sample Rate: 1 GS/s on each channel. Sensitivity (with calibrated fine adjustment): 2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div, in all modes, and 20 MHz at 10 mV/div in Peak Detect mode). DC Gain Accuracy: ± 3%. (± 4% at 2 mV/div and 5 mV/div). Vertical Resolution: 8 bits (256 levels over 10.24 vertical divisions). Acquisition Modes: Sample, Average, Peak Detect; High frequency and random glitch capture; captures glitches as narrow as 10 ns using acquisition hardware at all time/div settings between 5 us/div and 5 s/div. Time/Division Range: 5 ns to 5 s/div. Record Length: 2500 sample points per channel. Horizontal Accuracy: ± 0.01 %. Waveform Storage: Two 2500 point reference waveforms. Trigger Type: Edge (Rising or Falling), Video, Set to 50%. Trigger Source: CHI, CH2, Ext, Ext/5 and AC Line. Cursor Types: Voltage, Time. Backlit LCD with adjustable multilevel contrast. GPIB



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS 220. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your TEKTRONIX TDS 220 REPAIR and/or TEKTRONIX TDS 220 2 Ch 100 MHz Digital Storage Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: