A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS620A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS620A   Description / Specification:    
TEKTRONIX TDS620A 4-Ch 500 MHz Digitizing Oscilloscope

The Tektronix TDS620A 500 MHz Digitizing Oscilloscope. Specifications. Channels: 2 + 2 auxiliary. Max Sample Rate: 2 GS/s (Single channel). DC Gain Accuracy - ± 1.5%; Vertical Resolution - 8 bits (256 levels over 10.24 vertical divisions). Analog Bandwidth Selections - 20 MHz, 100 MHz, and full. Input Coupling - AC, DC or GND. Input Impedance Selections - 1 M-ohm in parallel with 10 pF, or 50 ohm (AC and DC coupling) . Maximum Input Voltage - ±400 V (DC + peak AC). Derate at 20 dB/decade above 1 MHz, 1 M-ohm or GND coupled. Channel Isolation - > 100:1 at 100 MHz and >30:1 at bandwidth for any two channels having equal Volts/div settings. AC Coupled Low Frequency Limit - <= 10 Hz when AC 1 M-ohm coupled. <= 200 kHz when AC 50 ohm coupled. Time Bases - Main, Delayed. Time/Division Range - 500 ps to 5 s/div. Time Base Accuracy - ± 100 ppm over any interval >= 1 ms. Record Length - 500 to 2000 pts. Triggers - Main, Delayed. Main Trigger Modes - Auto, Normal, Single. Time Delay Range - 16 ns to 250 s (time/div <= 10 us); 15.1 ns to 250 s (time/div >=25 us). Monochrome CRT, 7 in. diagonal, magnetic deflection. Horizontal raster-scan. P4 White phosphor.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS620A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your TEKTRONIX TDS620A CALIBRATION and/or TEKTRONIX TDS620A 4-Ch 500 MHz Digitizing Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: