TEKTRONIX TDS 654C REPAIR and TEKTRONIX TDS 654C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX TDS 654C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS 654C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS 654C (TDS654C)   Description / Specification:    
TEKTRONIX TDS 654C

500 MHz Digital Storage Oscilloscope. Total Channels: 4. Sample Rate ( all channels simultaneously): 5 GS/s. Time Bases: Main and delayed. Time/div Range: 200 ps/div to 10 s/div. Time Base Accuracy: Over any interval > 1 ms 100 ppm. Time Interval Measurement Accuracy : ±[(0.2/sample rate) + (100 ppm x |Reading|] single shot. ( 50 ps @ 5 GS/s). Record Length per Channel: 500 to 15.000 pts. Trigger Jitter: 8 ps RMS (typical). Pre-Trigger Position: 0% to 100% of record. Channel to Channel Deskew Range: ±25 ns. Vertical Resolution: 8-Bits (> 11 -Bits with averaging). Vertical Sensitivity: 1 mV/ div to 10 V/div. Maximum Input Voltage: 300 V CAT II; ±400 V peak. Derate at 20 dB/decade above 1 MHz. DC Gain Accuracy: ±1.5%. Position Range: ±5 divs. Offset: ± 1 V from 1 to 99.5 mV/div, ± 10 V from 100 mV to 995 mV/div, ± 100 V from 1 V to 10 V/div. Bandwidth Selections - 20 MHz, 250 MHz and Full. Input Impedance Selections: 1 M-Ohm in parallel with 10 pF. or 50 ohm (AC and DC coupling). Input Coupling: AC. DC or GND. AC Coupled Low Frequency Limit: <10 Hz when AC. 1 M-Ohm coupled. <200 kHz when AC. 50 ohm coupled. Color CRT Monitor 7 in. diagonal NuColor"' liquid crystal full-color shutter, 256 levels.



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS 654C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX TDS 654C REPAIR and/or TEKTRONIX TDS 654C CALIBRATION

I'm interested in: 
Calibration Type (Select one):
 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province:
Zip/Postal Code:
Phone:*

Comment: