TEKTRONIX TDS 694C REPAIR and TEKTRONIX TDS 694C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX TDS 694C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS 694C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS 694C (TDS694C)   Description / Specification:    
TEKTRONIX TDS 694C

3 GHz Digital Storage Oscilloscope. Total Channels: 4. Sample Rate ( all channels simultaneously): 10 GS/s. Time Bases: Main and delayed. Time/div Range: 100 ps/div to 10 s/div. Time Base Accuracy: Over any interval> 1 ms ± 10 ppm. Time Interval Measurement Accuracy : ±[(0.15/sample rate) + (10 ppm x |Reading|] single shot. ( 15 ps @ 10 GS/s). Record Length per Channel: 500 to 30,000 pts. (optional: 120,000 pts.) Trigger Jitter: 8 ps RMS (typical). Pre-Trigger Position: 0% to 100% of record. Channel to Channel Deskew Range: ±25 ns. Vertical Resolution: 8-Bits (> 11 -Bits with averaging). Vertical Sensitivity: 10 mV/div to 1 V/div. Maximum Input Voltage: 5 V RMS. DC Gain Accuracy: ±1.0%. Position Range: ±5 divs. Offset: ±0.5 V from 10 to 50 mV/div, ±0.25 V from 50.5 to 100 mV/div, ±5 V from 101 mV to 500 mV/div, ±2.5 V from 505 mV to 1 V/div. Bandwidth Selections: Full only. Input Impedance Selections: 50 ohm (DC coupled). Input Coupling: DC or GND. Color CRT Monitor 7 in. diagonal NuColor"' liquid crystal full-color shutter, 256 levels.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS 694C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your TEKTRONIX TDS 694C REPAIR and/or TEKTRONIX TDS 694C CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: