TEKTRONIX TDS7404 REPAIR and TEKTRONIX TDS7404 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX TDS7404. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS7404 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS7404   Description / Specification:    
TEKTRONIX TDS7404 4 Ch 4 GHz Digital Phosphor Oscilloscope

The Tektronix TDS7404 4 Ch 4 GHz Digital Phosphor Oscilloscope features exceptional signal acquisition and analysis, operational simplicity and complete connectivity to your design environment and third party analysis software. The intuitive user interface, developed after months of customer research, was pioneered in the TDS7404. With single-shot sample rates to 20 GS/s, easily meet the demands of the latest high-speed logic families and multi-Gigabit communication standards. Acquisition memory up to 32 Megasamples maximizes the value of the high sample rate and ensures that critical events are captured with fine detail. Exceptional deltatime measurement performance provides dependably accurate measurements of the time interval between two events. And, the combination of exceptional trigger and acquisition performance, deep memory and application-specific software make the TDS7000 Series a high-performance jitter and timing analysis tool. The Tektronix TDS7404 includes the TekConnectTM signal interconnect system, which further ensures superior signal fidelity, while offering unparalleled versatility with the world’s widest array of accessory signal acquisition solutions for high-performance, real-time oscilloscopes. Specifications. Input Channels: 4. Analog Bandwidth (–3 dB): 4 GHz. Calculated Rise Time 10 mV/div to 1 V/div: 100 ps. Input Coupling: DC, Gnd. Input Impedance: 50 ohm ±2.5%. Vertical Resolution: 8-Bit (>11-Bit with averaging). Max Input Voltage, 50 ohm: Determined by TekConnect Accessory. DC Gain Accuracy: ±(2% + (2% * offset)). Time Base Range: 50 ps/div to 10 s/div. Time Base Delay Time Range: 16 ns to 250 s. Channel-to-channel Deskew Range: ±25 ns. Real-time Sample Rates: 1 channel (max) 20 GS/s, 2 channel (max) 10 GS/s, 3 or 4 channel (max) 5 GS/s. Maximum Record Length per Channel with Standard Memory:400 k (1-CH.), 200 k (2-CH.), 100 k (4-CH.). Time Resolution (Single-shot): 50 ps (20 GS/s). Max Duration with Standard Memory: 20 µs. Trigger Sensitivity Internal DC Coupled: 0.35 div DC to 50 MHz increasing to 1.5 div at 3 GHz. Options. 1M, 2 Msamples max, 500 ksamples/ch. 2M, 8 Msamples max, 2 Msamples/ch. 3M, 16 Msamples max, 4 Msamples/ch. 4M, 32 Msamples max, 8 Msamples/ch. J1, TDSJIT2 Jitter Analysis Software. J2, TDSDDM2 Disk Drive Analysis Software. CP2 (Requires Option SM), TDSCPM2-ANSI/ITU Telecom Pulse Compliance Testing. USB, TDSUSBS-USB2.0 Compliance Test S/W Only. SM, Serial Comm Mask Testing. ST, Serial Pattern Trigger. UBF, USB Test Fixture.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS7404. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX TDS7404 REPAIR and/or TEKTRONIX TDS7404 4 Ch 4 GHz Digital Phosphor Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: