TEKTRONIX THS720A REPAIR and TEKTRONIX THS720A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX THS720A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX THS720A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX THS720A (THS 720A)   Description / Specification:    
TEKTRONIX THS720A

100 MHz handheld battery operated Oscilloscope/DMM. Channels: Two. Sample Rate (Each Channel) 500 MS/s. Time/Division Range: 5 ns to 50 s/div. Sensitivity: 5 mV to 50 V/div (to 500 V/div with 10X probe). Position Range: ± 10 div. DC Gain Accuracy: ±2%. Vertical Resolution: 8-Bits. Record Length: 2500 points. Horizontal Accuracy: ±200 ppm. Roll Mode: >= 0.5 s/div. Autorange: User-selectable. Trigger Modes: Auto, Normal. DMM Specs; DC Voltage Ranges: 400.0 mV to 880 V. DC Volts Accuracy: ±(0.5% of reading + 5 counts). True RMS AC Voltage Ranges: 400.0 mV to 640 V. Maximum Float Voltage: 600 VRMS CAT II, each channel (probe dependent). Resolution: 4000 count, 3-3/4 digits. AC Volts Accuracy: ±(2% of reading + 5 counts). Resistance Ranges - 400.0 ohm to 40.00 M-Ohm. Resistance Accuracy - ±(0.5% of reading + 2 counts); 40 M-Ohm: ±(2% of reading + 5 counts). Diode Test Range: 0 to 2 V. Backlit LCD (320x240)



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX THS720A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your TEKTRONIX THS720A REPAIR and/or TEKTRONIX THS720A CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: