TEKTRONIX THS730A REPAIR and TEKTRONIX THS730A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX THS730A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX THS730A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX THS730A (THS 730A)   Description / Specification:    
TEKTRONIX THS730A

200 MHz handheld battery operated Oscilloscope/DMM. Channels: Two. Sample Rate (Each Channel) 1 GS/s. Time/Division Range: 2 ns to 50 s/div. Sensitivity: 5 mV to 50 V/div (to 500 V/div with 10X probe). Position Range: ± 10 div. DC Gain Accuracy: ±2%. Vertical Resolution: 8-Bits. Record Length: 2500 points. Horizontal Accuracy: ±200 ppm. Roll Mode: >= 0.5 s/div. Autorange: User-selectable. Trigger Modes: Auto, Normal. DMM Specs; DC Voltage Ranges: 400.0 mV to 880 V. DC Volts Accuracy: ±(0.5% of reading + 5 counts). True RMS AC Voltage Ranges: 400.0 mV to 640 V. Maximum Float Voltage: 600 VRMS CAT II, each channel (probe dependent). Resolution: 4000 count, 3-3/4 digits. AC Volts Accuracy: ±(2% of reading + 5 counts). Resistance Ranges - 400.0 ohm to 40.00 M-Ohm. Resistance Accuracy: ±(0.5% of reading + 2 counts); 40 M-Ohm: ±(2% of reading + 5 counts). Diode Test Range: 0 to 2 V. Backlit LCD (320x240)



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX THS730A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX THS730A REPAIR and/or TEKTRONIX THS730A CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: