YOKOGAWA DL708E-701820 REPAIR and YOKOGAWA DL708E-701820 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the YOKOGAWA DL708E-701820. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA DL708E-701820 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   YOKOGAWA DL708E-701820   Description / Specification:    
YOKOGAWA DL708E-701820 Digital Oscilloscope Mainframe

The Yokogawa DL708E-701820 Digital Oscilloscope Mainframe is designed for measuring multi-channel isolated physical signals. The modular inputs provide flexibility for various applications. The new DL708E-701820 provides data acquisition and recording technology to measure signals ranging from slow changing temperature to high-speed MHz signals. One instrument will provide a wide range of measurements. Features up to 8 channels, isolated inputs. Horizontal Max. record length: 400 k words (100 k words/ch model, standard), 4 M words (1 M word/ch model, when /M1 option is added), 8 M words (2 M word/ch model, when /M2 option is added), 16 M words (4 M word/ch model, when /M3 option is added). Sweep time: 100k words/ch model: 500 ns/div to 50000 s/div (1-2-5 steps), Other models: 500 ns/div to 100000 s/div (1-2-5 steps). 10 MS/s max. sampling rate, 10 bits 16 M words (with high-speed module). 100 kS/s max. sampling rate, 16 bits, 16 M words (with high-resolution module). Display: 10.4-inch TFT color liquid crystal display. RS-232-C interface, GP-IB interface. Plug-in modules. 701855, High-speed isolation module (12-bit A/D resolution). 701856, High-speed module (12-bit A/D resolution). 701852, High-resolution, high-voltage isolation module. 701853, High-resolution isolation module. 701857, High-resolution voltage/RMS isolation module. 701860, Temperature module. 701870, Logic input module. 701880, Strain module. 701885, Strain module (with shunt Cal).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA DL708E-701820. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your YOKOGAWA DL708E-701820 REPAIR and/or YOKOGAWA DL708E-701820 Digital Oscilloscope Mainframe CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: