YOKOGAWA WT210-760401 CALIBRATION and YOKOGAWA WT210-760401 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA WT210-760401 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   YOKOGAWA WT210-760401   Description / Specification:    
YOKOGAWA WT210-760401 Single-input Element Digital Power Meter

The Yokogawa 760401 WT210 Single-input Element Digital Power Meter has five times the high-frequency range and approximately twice the basic accuracy as the previous generations plus a high-speed data acquisition rate and a compact design make this digital power meter highly desirable. Wiring Type: Single-phase 2-wire. Specifications. Input type Voltage: Floating input, Resistance voltage divider. Input type Current: Floating input, Shunt input system. Rated values(ranges) Voltage: Crest factor 3, 15 / 30 / 60 / 150 / 300 / 600 V; Crest factor 6, 7.5 / 15 / 30 / 75 / 150 / 300 V. Rated values(ranges) Current: Crest factor 3 Direct input: 5 / 10 / 20 / 50 / 100 / 200 mA and 0.5 / 1 / 2 / 5 / 10 / 20 A; Crest factor 6 Direct input: 2.5 / 5 / 10 / 25 / 50 / 100 mA and 0.25 / 0.5 / 1 / 2.5 / 5 / 10 A. Maximum continuous allowed input voltage: Peak voltage of 2.0 kV or rms value of 1.5 kV (whichever is less). Maximum continuous allowed input current: 5 - 200 mA, Peak current of 30 A or rms value of 20 A (whichever is less); 0.5 - 20 A, Peak current of 100 A or rms value of 30 A (whichever is less). A/D converter simultaneous conversion of voltage and current inputs: Resolution 16 bits, Maximum conversion speed approximately 20 µs (approximately 51 kHz). Measurement functions. System: Digital sampling; sum of averages method. Frequency range: DC, and 0.5 Hz to 100 kHz. Crest factor: 3 or 6 (with rated input) 300 (with minimum effective input). Options. /C1, GP-IB communication interface. /C2, Serial (RS-232-C) communication interface. /EX1, External input 2.5/5/10 V. /EX2, External input 50/100/200 mV. /HRM, Harmonic measurement function. /DA4, 4-channel DA output. /CMP, Comparator and D/A, 4 channels each.



 

Standard Calibration $480.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA WT210-760401. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your YOKOGAWA WT210-760401 CALIBRATION and/or YOKOGAWA WT210-760401 Single-input Element Digital Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: